Flexible Hoses
FLANGE TYPE
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
F110 | FLANGE END | LAPPED FLANGE |
15A to 100A |
1.0MPa | 350ºC |
|
|
F115 | NON WELDING TYPE PUMP CONNECTOR | FLANGE | 20A to 300A |
1.0MPa of above *1 |
300ºC *5 |
|
|
F118 | NON WELDING TYPE PUMP CONNECTOR | FLANGE | 20A to 50A |
1.0MPa | 350ºC |
|
|
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
F120 | FLANGE END | LAPPED OR FIXED FLANGE THREADS | 10A to 350A |
1.0MPa of above *1 |
350ºC *3 |
|
|
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
F130 | FIRE- EXTINGUISHING EQUIPMENT FLEXIBLE JOINT |
FLANGE (JIS10K) |
32A to 300A |
1.4MPa | 20ºC *4 |
|
|
F135 | FIRE- EXTINGUISHING EQUIPMENT FLEXIBLE JOINT |
FLANGE (JIS20K) |
32A to 200A |
2.8MPa | 20ºC *4 |
|
|
F138 | FIRE- EXTINGUISHING EQUIPMENT FLEXIBLE JOINT |
FLANGE (JIS10K) |
32A to 50A |
1.4MPa | 20ºC *4 |
|
|
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
F140 | OFFICIALLY CERTIFIED FLEXIBLE JOINT (JAPAN) | LAPPED OR FIXED FLANGE | 40A to 350A |
1.0MPa | 100ºC *4 |
|
|
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
F150 | FLANGE END LAYING UNDER THE GROUND TYPE | LAPPED OR FIXED FLANGE | 10A to 350A |
1.0MPa of above *1 |
80ºC |
|
|
F155 (SEMI) |
SEMI-JACKET TYPE | LAPPED OR FIXED FLANGE THREADS | 10A to 350A |
1.0MPa of above *1 |
350ºC *3 |
|
|
F155 (FULL) |
FOR COOLANT PIPING | FIXED FLANGE | 10A to 350A |
1.0MPa of above *1 |
350ºC *3 |
|
|
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
F165 | FOR COOLANT PIPING | LAPPED OR FIXED FLANGE THREADS | 15A to 200A |
1.0MPa of above *1 |
-196ºC to 80ºC |
|
|
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
T670 | FLUORO- PLASTIC LINED TUBES |
LAPPED OR FIXED FLANGE | 15A to 350A |
*1 | 270ºC *3 |
|
|
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
B710 | NON WELDING TYPE PUMP CONNECTOR | FLANGE | 50A to 300A |
1.0MPa | - |
|
|
B720 | NON WELDING TYPE PUMP CONNECTOR | FLANGE | 50A to 300A |
2.0MPa | - |
|
|
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
E410 | BELLOWS TYPE EXPANSION JOINT | FIXED FLANGE |
20A to 200A |
1.0MPa | 220ºC *4 |
|
|
E420 | BELLOWS TYPE EXPANSION JOINT | FIXED FLANGE |
20A to 200A |
1.0MPa | 220ºC *4 |
|
|
*1. Decided by the kind of tubes type.
*2. Decided by the kind of fittings .
*3. Decided by NOMINAL DIA. and the kind of tubes and fittings type.
*4. Decided by the application standards.
*5. Decided by the kind of fittings packing.
THREADS TYPE
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
S210 | NON WELDING TYPE FEMALE UNIONS END | FEMALE THREADS | 15A to 50A |
1.0MPa | 100ºC |
|
|
S215 | NON WELDING TYPE CONNECTION BETTWEEN NUT AND TUBES | MALE OR FEMALE THREADS | 8A to 25A |
1.0MPa of above *1 |
100ºC |
|
|
S220 | FEMALE UNIONS END | FEMALE THREADS | 8A to 100A |
1.0MPa of above *1 |
350ºC *3 *5 |
|
|
S221 | CORE UNIONS END | FEMALE THREADS | 15A to 50A |
1.0MPa | *2 |
|
|
S222 | FEMALE UNIONS END | FEMALE THREADS | 6A to 100A |
1.0MPa of above *1 |
350ºC *3 |
|
|
S225 | SWIVEL COUPLING WITH METAL TO METAL SEAL | MALE OR FEMALE THREADS | 6A to 65A |
1.0MPa of above *1 |
350ºC *3 |
|
|
S227 | FEMALE SWIVEL END | FEMALE THREADS | 8A to 65A |
1.0MPa of above *1 |
350ºC *3 |
|
|
S228 | SWIVEL COUPLING WITH METAL TO METAL SEAL | MALE OR FEMALE THREADS | 6A to 65A |
1.0MPa of above *1 |
350ºC *3 |
|
|
S230 | THREADED END | MALE OR FEMALE THREADS | 6A to 100A |
1.0MPa of above *1 |
350ºC *3 |
|
|
S270 | TANKER JOINT | THREADS | - | 1.0MPa of above *1 |
350ºC *3 |
|
|
*1. Decided by the kind of tubes type.
*2. Decided by the kind of fittings .
*3. Decided by NOMINAL DIA. and the kind of tubes and fittings type.
*4. Decided by the application standards.
*5. Decided by the kind of fittings packing
COUPLING TYPE
TYPE NUMBER |
DETAIL | TYPE NAME | FITTINGS | NOMINAL DIA. |
WORKING PRESSURE |
MAX. TEMPERATURE |
APPLICATION |
C310 | CAM-LOCK END | CAM-LOCK | 15A to 150A |
1.0MPa of above *2 |
*5 |
|
|
C315 | QUICK COUPLING | QUICK COUPLING | 8A to 50A |
1.0MPa of above *2 |
*5 |
|
|
C320 | PIPE END | STEEL PIPE OR COPPER PIPE | 6A to 350A |
1.0MPa of above *1 |
*3 |
|
|
C325 | COUPLING CONNECTION | COUPLING CONNECTION | 25A to 50A |
- | 80ºC *3 |
|
|
C330 | COPPER SOCKET END | COPPER SOCKET | 8A to 80A |
1.0MPa of above *1 |
*3 |
|
|
C340 | SANITARY FITTINGS END | FLANGE OR THREADS | 6A to 200A |
1.0MPa of above *1 |
*5 |
|
|
*1. Decided by the kind of tubes type.
*2. Decided by the kind of fittings .
*3. Decided by NOMINAL DIA. and the kind of tubes and fittings type.
*4. Decided by the application standards.
*5. Decided by the kind of fittings packing.